Image photometry: Polarimetry


  

1716       02:36 صباحاً       التاريخ: 27-8-2020              المصدر: A. Roy, D. Clarke

أقرأ أيضاً
التاريخ: 2023-03-25 733
التاريخ: 2023-08-08 617
التاريخ: 12-8-2020 1558
التاريخ: 30-7-2020 1170
التاريخ: 4-9-2020 1450
Image photometry: Polarimetry
 
In order to make measurements of polarization in the optical region, the necessary related photometric determinations need to be made with high accuracy. Most precision polarimeters, therefore, make use of photoelectric detectors and, as a consequence, they are able to make measurements of only one star at a time. There are several designs of photographic polarimeter which allow star field surveys to be undertaken but the results from individual stars are of inferior quality in comparison with the photoelectric measurements.
In the optical region, the amount of polarization in the light from an astronomical object is usually very small and great care is needed to avoid the introduction of systematic errors. In principle, the polarization can be measured by rotating polarization-sensitive optical elements in the beam, prior to the detector. The simplest design would use a piece of Polaroid in the beam and would require the signal output to be recorded as the rotational setting of the Polaroid is adjusted. A more elegant version would use amore efficient polarizer in the form of a birefringent prism. The improvement might require the use of an extra lens to provide a collimated beam for the prism. The basic elements of this type of polarimeter are illustrated in figure 1. Non-polarizing colour filters may be used to limit the spectral passband. Calibration filters may also be available so that known amounts of polarization may be added and the instrument’s response checked. From the experiences of various observers, catalogues of stars exhibiting zero polarization and others with accurately determined values have been established for reference measurement and these are constantly under review.
src=../../../medea/images/000_35.png
Figure 1. A single-beam polarimeter.


Untitled Document
د. فاضل حسن شريف
يوم الغدير كذلك جعل فيه عيسى عليه‌ السلام شمعون...
حسن الهاشمي
الآثار الوضعية للذنوب... سيدتي لكي تبتعدي عن الزنا...
د. فاضل حسن شريف
يوم الغدير كذلك نصب فيه موسى عليه‌ السلام وصيه يوشع بن...
محمدعلي حسن
ما عقاب الحاسد؟
د. فاضل حسن شريف
يوم الغدير كذلك جعل الله تعالى النار فيه على إبراهيم...
جواد مرتضى
المباهلة
د. فاضل حسن شريف
يوم الغدير كذلك انتصر فيه موسى عليه السلام على السحرة...
جواد مرتضى
نبذة من سيرة الامام الهادي (عليه السلام)
د. فاضل حسن شريف
الشهادة الثالثة و مفردات من القرآن الكريم (أشهد أن) (ح 12)
زيد علي كريم الكفلي
مَسِيرَةٌ الْمَنَايَا...الْإِمَامُ الْحُسَيْنُ...
زيد علي كريم الكفلي
لَا شَيْءَ يُعْجِبُنِي ....
علي الحسناوي
امتيازات الشهادة التي يحصل عليها الموظف اثناء الخدمة
طه رسول
كيمياء الشاي: سحر العلوم في كوبك!
منتظر جعفر الموسوي
النمو الاقتصادي وتعزيز البنى التحتية للدول